<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Troubleshooting on DaltonFarm0</title><link>https://thedaltonfarm.com/tags/troubleshooting/</link><description>Recent content in Troubleshooting on DaltonFarm0</description><generator>Hugo</generator><language>en-us</language><lastBuildDate>Fri, 20 Dec 2024 00:00:00 +0000</lastBuildDate><atom:link href="https://thedaltonfarm.com/tags/troubleshooting/index.xml" rel="self" type="application/rss+xml"/><item><title>Configuration Manager Cloud Attach Error: (401) Unauthorized</title><link>https://thedaltonfarm.com/blog/cloudattach401error/</link><pubDate>Fri, 20 Dec 2024 00:00:00 +0000</pubDate><guid>https://thedaltonfarm.com/blog/cloudattach401error/</guid><description>&lt;h1 id="configmgr-cloud-attach-error-401-unauthorized"&gt;ConfigMgr Cloud Attach Error: (401) Unauthorized&lt;/h1&gt;
&lt;p&gt;&lt;strong&gt;CMGatewayNotificationWorker&lt;/strong&gt;&lt;/p&gt;
&lt;pre tabindex="0"&gt;&lt;code&gt;[Warning][CMGatewayNotificationWorker][0][System.Net.WebException][0x80131509]
The remote server returned an error: (401) Unauthorized.
at Microsoft.ConfigurationManager.ServiceConnector.ExtensionMethods.d__13.MoveNext()
&lt;/code&gt;&lt;/pre&gt;&lt;p&gt;I struggled with this one while setting up Co-management testing in Microsoft Configuration Manager.&lt;br&gt;
Cloud Attach completed successfully — everything looked good. I entered my Entra ID Global Admin credentials and all indicators turned green.&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;But nothing would sync.&lt;/strong&gt;&lt;/p&gt;</description></item><item><title>Configuration Manager Software Updates Error 0x800F0831</title><link>https://thedaltonfarm.com/blog/suerror0x800f0831/</link><pubDate>Thu, 23 Mar 2023 00:00:00 +0000</pubDate><guid>https://thedaltonfarm.com/blog/suerror0x800f0831/</guid><description>&lt;h1 id="configuration-manager-software-updates-error-0x800f0831"&gt;Configuration Manager: Software Updates Error 0x800F0831&lt;/h1&gt;
&lt;p&gt;I came across this issue in Configuration Manager while attempting to patch a Server OS.&lt;/p&gt;
&lt;p&gt;&lt;img src="https://thedaltonfarm.com/image-5.png" alt="Update failure screenshot"&gt;&lt;/p&gt;
&lt;p&gt;The error:&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;Failed to Install Updates — 0x800F0831 (Unknown Error -2146498511)&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;occurs when a &lt;strong&gt;pre-requisite update is missing&lt;/strong&gt; from the system.&lt;/p&gt;</description></item><item><title>Configuration Manager Feature Update Loop</title><link>https://thedaltonfarm.com/blog/sccmfeatureupdateloop/</link><pubDate>Sun, 26 Jun 2022 00:00:00 +0000</pubDate><guid>https://thedaltonfarm.com/blog/sccmfeatureupdateloop/</guid><description>&lt;h1 id="fix-sccm-feature-update-loop-troubleshooting-guide"&gt;Fix SCCM Feature Update Loop: Troubleshooting Guide&lt;/h1&gt;
&lt;p&gt;To understand this problem, remember that SCCM is only attempting to launch the setup file for the feature update. The feature update is failing, and SCCM continues to try to run the setup. As part of the setup process the PC must reboot—hence the loop after the setup failure.&lt;/p&gt;</description></item></channel></rss>